CR-KK600 Automatic Open Cup Flash Point Tester

$1,250.00

This instrument is primarily designed for determining the open cup flash point and fire point values ​​of petroleum products. Utilizing an electric ignition method, it requires no combustible gases and fully complies with the methodological requirements of ASTM D92 (GB3536-2008) and GB267-88. The instrument incorporates a suite of cutting-edge technologies, including a high-performance ARM series microprocessor, electrically erasable memory (capable of storing tens of thousands of data records), a color LCD touchscreen interface, and PID auto-tuning capabilities. These features endow the instrument with the following characteristics: 1. Powerful Functionality: It serves a dual purpose, simultaneously determining both the flash point and fire point while printing the test results; furthermore, it features an internal real-time clock chip that automatically displays the current date and time, with data retention capabilities in the event of a power failure. 2. High Accuracy: Temperature errors are controlled within a tolerance of ±1.5°C, with a resolution of 0.1°C. 3. Excellent Repeatability: Provided that the testing environment adheres to the standards of GB3536 (ASTM D92) or GB/T 267-88, consecutive tests performed on the same sample will yield flash point values ​​differing by no more than 4°C. 4. High Degree of Automation: The instrument is capable of automatically executing the entire testing process—including cooling cycles and automated informational prompts—without manual intervention. In terms of functionality and performance, this open cup flash point tester aligns with the highest international and domestic standards, making it an ideal specialized instrument for replacing imported equipment across industries such as petroleum, electric power, chemical engineering, and commercial inspection.

Instrument Features

  • The display features an original, imported 7.0-inch true-color TFT-LCD screen, while the keypad utilizes a human-sensing touch interface. With a fully Chinese-language operating interface, the display offers a delicate, intuitive, and elegant visual presentation, ensuring convenient operation and responsive touch control.
  • Historical data is stored in NVM memory, capable of archiving 20,000 data entries. This data is retained for up to 10 years without loss and remains tamper-proof once stored.
  • The device is equipped with a miniature embedded thermal printer, ensuring quieter, faster, and clearer printouts.
  • Temperature measurement and control are driven by an original, imported PT100 platinum resistance temperature sensor, a high-precision AD converter, a superior mathematical linearization model, and a unique control algorithm, resulting in faster, more accurate, and more stable temperature monitoring.
  • Ignition is achieved via direct electronic flame ignition—functionally identical to traditional gas-flame ignition—offering a safe, convenient, and reliable solution free from interference.
  • Flash point detection employs high-frequency ion-ring flame sensing technology, enabling the rapid and accurate capture of the sample’s instantaneous flash point while preventing both false positives and missed detections.
  • Atmospheric pressure measurement utilizes a fully digital atmospheric pressure sensor imported from Germany. It measures local atmospheric pressure in real-time and automatically compensates for the impact of atmospheric pressure fluctuations on the measurement data.
  • The device automatically executes all operational steps, including heating, detection, calculation, and printing.

Instrument Parameters:

  • Measurement Range: Room Temperature – 400°C
  • Temperature Detection: Platinum Resistance Thermometer
  • Sensitivity: 0.1°C
  • Repeatability: Compliant with GB3536-2008 (ASTM D92) and GB/T 267-88
  • Display: 7-inch Color LCD Touchscreen
  • Data Storage: Stores up to 20,000 measurement results
  • Ignition Method: Electric Ignition | Cooling Method: Forced Air Cooling
  • Printer: Chinese Character Display, 40 Lines
  • Self-Check Functions: Lifting rod, sweeping rod, printing, etc.
  • Power Consumption: ≤ 600 VA
  • Power Supply: AC 220 V ± 11 V, Frequency 50 Hz ± 2.5 Hz
  • Ambient Temperature: 10 – 35°C

 

Color

Black

Material

Aluminium, Fabric

Reviews

There are no reviews yet.

Be the first to review “CR-KK600 Automatic Open Cup Flash Point Tester”

Your email address will not be published. Required fields are marked *

Fringilla phasellus faucibus

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Fringilla ut morbi tincidunt augue interdum velit. Cursus in hac habitasse platea dictumst quisque sagittis purus. Dignissim convallis aenean et tortor at risus.

Maecenas pharetra convallis posuere morbi. Vulputate odio ut enim blandit volutpat maecenas. Tristique sollicitudin nibh sit amet commodo nulla. Congue mauris rhoncus aenean vel elit scelerisque.

Duis tristique sollicitudin

In tellus integer feugiat scelerisque varius morbi enim. Tristique senectus et netus et malesuada fames ac turpis egestas. A diam sollicitudin tempor id eu nisl. Adipiscing elit duis tristique sollicitudin nibh sit amet commodo.

  • Mattis pellentesque id nibh tortor id aliquet
  • Nulla facilisi cras fermentum
  • Commodo nulla facilisi nullam vehicula

In cursus turpis massa tincidunt dui ut. Nulla facilisi cras fermentum odio eu feugiat. Vulputate odio ut enim blandit volutpat maecenas volutpat blandit. Tellus molestie nunc non blandit massa enim nec dui. Lectus magna fringilla urna porttitor rhoncus.

Secure Payments

Tellus gravida ipsum aut facilisis tempus at et aliquam estsem.

Free Shipping

Non pulvinar aenean ultrices lectus vitae imperdiet vulputate a eu.

Gifts & Sales

Aliquet ullamcorper leo mi vel sit pretium euismod eget libero.

24/7 Support

Nullam iaculis vestibulum arcu id urnain pellentesque volutpat quis.

CR-KK600 Automatic Open Cup Flash Point Tester
CR-KK600 Automatic Open Cup Flash Point Tester

$1,250.00

Add to cart